Performance
   

Summary of Removal
  Avg. NH4
(mg N/L)
Avg. NH3
(mg N/L)
Avg. TKN
(mg N/L)
Avg. total N (mg N/L) Avg. % N removal Avg. BOD (mg/L) Avg. COD (mg/L) Avg. % COD removal
Triple Tree 1.2 2.3 5.1 7.3 85.1% 54.7 94.0 68.1%
Church 9.2 1.3 16.5 17.7 81.0% 65.9 137.6 88.2%
Valley View 9.7 2.6 12.6 15.5 69.0% 25.7 98.0 64.9%
Osprey 5.8 7.7 9.7 17.4 73.0% N/A N/A N/A
Burnt Road 6.6 4.3 11.7 16.2 78.5% 34.9 72.6 83.3%

Influent Parameters
  # of Bedrooms Flow Average Flow Peak (gpd) Average NH4 Average NO3 Average TKN Average Total N Avg. COD/BOD Average pH
Triple Tree 5 145 313 44.7 .05 49.4 49.9 298.8 6.8
Church 3 261 465 78.1 0.0 95.2 95.2 1144.75 N/A
Valley View 3 147.7 520 48.2 2.3 52.7 52.7 317 8
Osprey 3 276 500 64.3 0.22 69.95 70.04 246 6
Burnt Road 2 80 164 34 0.6 47.3 59 310.5 7.5

  • Units are tested in cold weather environments and still provide greater than 70% nitrogen removal.
  • Eliminite provides significant BOD and COD removal as well as nitrogen removal.
  • Data has been collected since 1994 and the removal efficiency has not diminished.
Percentage of Nitrogen Removal in Effluent Church Street System

click to enlarge

Percentage of Nitrogen Removal from Osprey Study   Effluent

click to enlarge

The percentage of removal data shown above was achieved during the study for the Department of Natural Resources and Conservation, Helena, Montana. The study looked at three alternative septic systems. The study was written and directed by Osprey Environmental Consulting.